We are NFI trained and factory certified

Flame Center has gone above and beyond the normal license requirements to be an installation company in order to ensure your safety and provide you with the comfort of knowing that the best, most knowledgeable technician has installed your fireplace or stove. As our staff is continually updating their certifications, you can rest assured that your home is always in safe hands. Furthermore, just like we would in our own homes, the Flame Center crews always tread lightly and clean up after themselves.

We completely understand the financial commitment you've made to us. We want you to feel good about every aspect of your install. Knowing you are in the best hands possible. Saftey and communication is our top priority. Our lead installers have the most up to date resources, and the best possible team standing behind them.

We are insured and licensed for the work we do and are the very best at it.

 

Let us install it for you. Call 616-662-4400 to schedule a Job Check!

Proudly Serving Grand Rapids, Holland, Spring Lake, Grand Haven, East Grand Rapids, Ada, Saugatuck, Douglas and Surrounding Areas

Here are some installation examples...

 

 

Contact Us Today!

Words to help you along the way
 

Input Rate:  The rate at which gas is supplied to an appliance.  This is usually mentioned in BTU per hour.

Vent, Flue:  A passageway for transporting gases to the outside air.

Oxygen Depletion Sensor (ODS):  This is a device used in ventless products that shuts off the flow of gas if the oxygen level in the room falls to 18%.

Millivolt:  1mv is 1/1000 of a volt.  Millivolt's are generated by heat from the pilot burner flame.  Thus no electricity is needed to power a millivolt valve system (a millivolt valve system will operate during power failures).

Thermocouple:  Heat from the pilot will generate 24mv to 30mv.  This in turn holds the electomagnetic coil open, allowing gas to enter the valve body and hold a pilot flame.  It also acts as a safety device that will shut off the gas supply to the main burner and pilot when no flame (heat) is sensed.

Thermopile/Generator: When heat is applied to the thermopile, an electric current is generated in the range of 450mv to 750mv. When the valve coil reaches the minimum required millivolts, the valve will open and gas will flow to the mainburner and ignite.

Thermodisk: A thermodisk is a temperature sensing device. When heat is applied to the disk, a bi-metal plate will bend. This allows the electric current to activate the blower motor and ensures continuity.

Spill Switch/Safety Shut Off Device: A temperature sensing device used on most vented appliances that will shut down the main burner and pilot if the unit has a blocked flue or if in a downdraft situation.

Cast Logs: Concrete based material. Glow is very minimal on logs. Dense material, holds heat in longer, and is less costly than fiber logs.

Fibre Logs: Ceramic fibre compound. When flame impinges on the logs, it produces a red glow on the logs. Very lightweight and fragile material.